Standby at 500 °C: temperature field and balance of the case shown. Holding power of about 5.91 kW. Screenshot supplied by the author.Click to enlarge
A sand battery stores energy as heat. Resistors heat the gas of a closed circuit; the gas flows through a pipe network in the bed and gives up its heat there. On discharge, a heat exchanger returns it to the user. The simulator follows bed, casing and circuit together to study temperatures, losses and useful power.
- Goal
- How does heat distribute in the bed? How much is lost in standby, and how do charge and discharge evolve? The model also lets you examine the flow rates in the pipes and the fan power required.
- Method
- The 3D temperature field is solved by finite volumes on an adaptive mesh, with temperature-dependent materials and bed conductivity. A coupled network describes pipe–bed exchange, gas mixing, pressure losses and flow distribution. Transients include an energy balance at every step.
- Development and features
- I developed the solver and the GUI with PySide6 and PyVista. You configure the tank, insulation, ground and pipe network; you can size the gas distribution and check mesh convergence before running standby or transients. The 3D view sits next to temperatures, powers, balances and time series. States can be saved and resumed; data export to CSV and the field to VTK. The gallery distinguishes the standby case supplied by the author from the illustrative 24-hour charge.
Screens and results
Geometry and results
The cover shows standby at 500 °C. The following screens document the 24-hour charge at 200 kW.
01
Geometry and gas circuit
The tank, the insulation layers and the pipe network define the path of the heat. The 3D view lets you check the geometry before reading the results.
02
Transient simulation
The charge case starts at 20 °C with a constant power of 200 kW. The GUI shows the temperature field and the time samples of the simulation, on a 3,032-cell mesh with a 900 s time step.
03
24-hour charge
I ran this example with a constant 200 kW for 24 hours, starting from 20 °C. The mean sand temperature reaches about 194 °C, while the local maximum exceeds 518 °C: a mean temperature alone does not describe how the heat is distributed.
Download the case data · CSV04
Energy balance
Next to the 3D field, the GUI shows energy input and stored, losses, gas temperatures, pressure drop and fan power. In the transient, the net heat input changes the state of the system: the balance must be read together with the time evolution.